Код товара: ct109228

Система хранения данных Lenovo Storwize V3700 V2 [6535N1F]

Артикул: 6535N1F Код товара: ct109228

СХД Lenovo (IBM) V3700 V2 LFF Expansion Enclosure

Цена: 447 842 

под заказ

0 Смотрят этот товар прямо сейчас!
Внешний вид товара, комплектация и характеристики могут отличаться от действительности. При заказе оборудования, проверяйте заявленные характеристики на официальных сайтах производителя или через наших менеджеров.
Описание
Component Specification
Form factor Lenovo Storage V3700 V2 Expansion Enclosure: 2U rack mount
Controller
configuration
Dual controller (known as node canister) configuration.
RAID levels RAID 0, 1, 5, 6, and 10; Distributed RAID 5 and 6.
Controller cache 16 GB per system (8 GB per node canister). V3700 XP is upgradeable to 32 GB (16 GB per node canister). Cache mirroring between the node canisters. Flash-backed cache protection (includes battery).
Drive bays Up to 240 SFF drive bays per storage system:

  • 24 SFF drive bays in the control enclosure
  • 24 SFF drive bays in the expansion enclosure; up to 9 expansion enclosures

Up to 120 LFF drive bays per storage system:

  • 12 LFF drive bays in the control enclosure
  • 12 LFF drive bays in the expansion enclosures; up to 9 expansion enclosures

Intermix of SFF and LFF enclosures is supported.

Drive technology SAS and NL SAS HDDs and SAS SSDs. Intermix of HDDs and SSDs is supported.
Drive connectivity

Dual-ported 12 Gb SAS drive attachment infrastructure.

Controller unit with two node canisters (ports per one node canister):

  • 24x 12 Gb SAS internal drive ports (SFF enclosure)
  • 12x 12 Gb SAS internal drive ports (LFF enclosure)
  • 1x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) expansion port for the attachment of the expansion enclosures

Expansion unit with two expansion canisters (ports per one expansion canister):

  • 24x 12 Gb SAS internal drive ports (SFF enclosure)
  • 12x 12 Gb SAS internal drive ports (LFF enclosure)
  • 2x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) expansion ports for the daisy chained attachment of the expansion enclosures
Drives SFF drives:

  • 300 GB and 600 GB 15K rpm SAS HDDs
  • 900 GB, 1.2 TB, and 1.8 TB 10K rpm SAS HDDs
  • 2 TB 7.2K rpm NL SAS HDDs
  • 400 GB, 800 GB, 1.6 TB, and 3.2 TB SAS SSDs
  • 1.92 TB and 3.84 TB read-optimized SAS SSDs

LFF drives:

  • 300 GB and 600 GB 15K rpm SAS HDDs
  • 900 GB, 1.2 TB, and 1.8 TB 10K rpm SAS HDDs
  • 4 TB, 6 TB, and 8 TB 7.2K rpm NL SAS HDDs
Storage capacity Up to 960 TB (120x 8 TB NL SAS HDDs)
Host connectivity Standard ports (per control enclosure with two node canisters):

  • 4x 1 Gb iSCSI host ports (UTP, RJ-45) (2 ports per node canister)
  • 4x 12 Gb SAS host ports (Mini-SAS HD, SFF-8644) (2 ports per node canister; V3700 V2 XP only)

Optional additional ports on host interface cards (per control enclosure with two node canisters):

  • 8x 12 Gb SAS host ports (Mini-SAS HD, SFF-8644) (4 ports per node canister)
  • 8x 1 Gb iSCSI host ports (UTP, RJ-45) (4 ports per node canister)
  • 8x 10 Gb iSCSI or FCoE SFP+ host ports (SW fiber, LC) (4 ports per node canister)
  • 8x 16 Gb FC SFP+ host ports (SW or LW fiber, LC) (4 ports per node canister)
Host operating systems Microsoft Windows Server 2012 and 2012 R2; Red Hat Enterprise Linux (RHEL) 6 and 7; SUSE Linux Enterprise Server (SLES) 11 and 12; VMware vSphere 5.1, 5.5, and 6.0.
Standard software features Virtualization of internal storage, Thin Provisioning, One-way Data Migration, FlashCopy snapshots (up to 64 targets), and Embedded GUI.
Optional software features FlashCopy snapshots upgrade (up to 2048 targets), Easy Tier, and Remote Mirroring.
Performance
(V3700 V2 / V3700 V2 XP)*
  • Up to 168,000 / 390,000 cache read IOPS
  • Up to 51,000 / 112,000 disk read IOPS
  • Up to 13,000 / 28,000 disk write IOPS
  • Up to 27,000 / 55,000 disk mixed (70% read/30% write) IOPS
  • Up to 3.4 / 6.2 GBps sequential disk read throughput
  • Up to 0.96 / 1.7 GBps sequential disk write throughput
Configuration maximums** Per system:

  • Maximum number of storage pools: 1,024
  • Maximum number of logical volumes: 2,048
  • Maximum logical volume size: 256 TB
  • Maximum number of drives in a RAID array: 16
  • Maximum number of RAID arrays: 128
  • Maximum number of drives in a distributed RAID array: 128 (including up to 4 spares)
  • Maximum number of distributed RAID arrays: 10
  • Maximum hot spare drives: No limit
  • Maximum number of host ports: 2,048
  • Maximum number of hosts: 256
  • Maximum number of host ports per one host: 32
  • Maximum number of snapshots: 2,048 (requires an optional license)
  • Maximum number of remote mirroring relationships: 2,048 (requires an optional license)
Cooling Redundant cooling with the fan modules that are built into power supplies.
Power supply Two redundant hot-swap 800 W AC power supplies.
Hot-swap parts Node canisters, expansion canisters, SFP/SFP+ transceivers, drives, power supplies with fans.
Management interfaces 2x 1 GbE ports (UTP, RJ-45) in a primary/redundant configuration.
Web-based GUI; SSH CLI; SMI-S; SNMP and email notifications.
Security features Secure Socket Layer (SSL), Secure Shell (SSH), user level security, LDAP authentication
Warranty Three-year customer-replaceable unit and onsite warranty with 9×5 next business day terms. Optional warranty service upgrades are available through Lenovo: 24×7 coverage, 2-hour or 4-hour response time, 6-hour or 24-hour committed repair, 1-year or 2-year warranty extensions, Hard Drive Retention.
Dimensions Height: 87 mm (3.4 in.); width: 483 mm (19.0 in.); depth: 556 mm (21.9 in.)
Weight
  • Control enclosure (fully configured): 26 kg (57.3 lb)
  • Expansion enclosure (fully configured): 26.7 kg (58.9 lb)
Характеристики

Характеристики: Система хранения данных Lenovo Storwize V3700 V2 [6535N1F]

Storage Capacity

Up to 960 TB (120x 8 TB NL SAS HDDs)

Security features

Secure Socket Layer (SSL), Secure Shell (SSH), user level security, LDAP authentication

Отзывы (0)
Обзор заказа
0
0
0
0
0

Отзывов пока нет.

Будьте первым, кто оставил отзыв на “Система хранения данных Lenovo Storwize V3700 V2 [6535N1F]”

Ваш адрес email не будет опубликован. Обязательные поля помечены *

1 2 3 4 5
1 2 3 4 5
1 2 3 4 5

Доставка и оплата

Интернет-магазин «СимплТех» предлагает купить Система хранения данных Lenovo Storwize V3700 V2 [6535N1F] с доставкой по Москве и всей России.

Доставка по Москве и Московской области

Осуществляется нашей курьерской службой по рабочим дням с 11 до 18 часов. Дата и время доставки согласовываются с Вами заранее.
Водитель не осуществляет подъем товара на этаж, а также не производит проверку оборудования.

Стоимость доставки

  • Самовывоз
В день оплаты, при наличии товара на складе
  • Курьерская доставка

— 600 рублей в пределах МКАД + 20 рублей / километр за МКАД.

— БЕСПЛАТНО при сумме заказа более 70 тысяч рублей + 20 рублей / километр за МКАД.

  • Транспортными компаниями
Доставка 6535N1F в другие города России осуществляется транспортными компаниями, имеющими пункт приема груза в Москве. Стоимость доставки рассчитывается согласно тарифам транспортных компаний.

Доставка программного обеспечения, лицензий и электронных компонентов осуществляется бесплатно по электронной почте на e-mail Заказчика по 100% предварительной оплате.

Внимание! Мы НЕ доставляем товары в Туркменистан, Казахстан, Грузию, Киргизию и другие страны СНГ.

Оплата товара в нашем Интернет-магазине производится по безналичному расчету.

Правила возврата платежей и товара

При покупке товара покупатель имеет право предъявить магазину требования о возврате или замене в течение 10 дней с момента его получения. Для возврата или обмена товара необходимо обратиться в магазин с соответствующим заявлением, приложив к нему документы о приобретении товара. При возврате или замене товара должны быть сохранены товарный вид, целостность упаковки и комплектация. Наличие следов эксплуатации может стать основанием для отказа в возврате. Доставка товара в магазин осуществляется за счет покупателя.

Обращаем Ваше внимание, что основная часть ассортимента нашего магазина относится к технически сложным товарам согласно Постановлению Правительства РФ № 924 от 10 ноября 2011 г. и не подлежит возврату или обмену на другой товар, за исключением случаев, предусмотренных действующим законом РФ «О защите прав потребителей» от 7 февраля 1992 г. № 2300-I.

Статьи и обзоры

Нет связанных новостей.